|
English
|
正體中文
|
简体中文
|
Post-Print筆數 : 27 |
Items with full text/Total items : 113656/144643 (79%)
Visitors : 51719391
Online Users : 617
|
|
|
Loading...
|
Please use this identifier to cite or link to this item:
https://nccur.lib.nccu.edu.tw/handle/140.119/65241
|
Title: | Sensitivity-encoded (SENSE) Proton Echo-Planar Spectroscopic Imaging (PEPSI) in Human Brain |
Authors: | Lin, Fa-Hsuan;Tsai, Shang-Yueh;Otazo, Ricardo;Caprihan, Arvind;Wald, Lawrence L.;Belliveau, John W. 蔡尚岳 |
Contributors: | 應物所 |
Keywords: | SENSE;PEPSI;parallel MRI;spectroscopic imaging;MRS |
Date: | 2007.02 |
Issue Date: | 2014-04-10 11:16:32 (UTC+8) |
Abstract: | Magnetic resonance spectroscopic imaging (MRSI) provides spatially resolved metabolite information that is invaluable for both neuroscience studies and clinical applications. However, lengthy data acquisition times, which are a result of time-consuming phase encoding, represent a major challenge for MRSI. Fast MRSI pulse sequences that use echo-planar readout gradients, such as proton echo-planar spectroscopic imaging (PEPSI), are capable of fast spectral-spatial encoding and thus enable acceleration of image acquisition times. Combining PEPSI with recent advances in parallel MRI utilizing RF coil arrays can further accelerate MRSI data acquisition. Here we investigate the feasibility of ultrafast spectroscopic imaging at high field (3T and 4T) by combining PEPSI with sensitivity-encoded (SENSE) MRI using eight-channel head coil arrays. We show that the acquisition of single-average SENSE-PEPSI data at a short TE (15 ms) can be accelerated to 32 s or less, depending on the field strength, to obtain metabolic images of choline (Cho), creatine (Cre), N-acetyl-aspartate (NAA), and J-coupled metabolites (e.g., glutamate (Glu) and inositol (Ino)) with acceptable spectral quality and localization. The experimentally measured reductions in signal-to-noise ratio (SNR) and Cramer-Rao lower bounds (CRLBs) of metabolite resonances were well explained by both the g-factor and reduced measurement times. Thus, this technology is a promising means of reducing the scan times of 3D acquisitions and time-resolved 2D measurements. Magn Reson Med 57:249–257, 2007. © 2007 Wiley-Liss, Inc. |
Relation: | Magnetic Resonance in Medicine ,57(2), 249-257 |
Data Type: | article |
DOI 連結: | http://dx.doi.org/10.1002/mrm.21119 |
DOI: | 10.1002/mrm.21119 |
Appears in Collections: | [應用物理研究所 ] 期刊論文
|
Files in This Item:
File |
Description |
Size | Format | |
21119.pdf | | 1052Kb | Adobe PDF2 | 1340 | View/Open |
|
All items in 政大典藏 are protected by copyright, with all rights reserved.
|
著作權政策宣告 Copyright Announcement1.本網站之數位內容為國立政治大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,惟仍請適度,合理使用本網站之內容,以尊重著作權人之權益。商業上之利用,則請先取得著作權人之授權。
The digital content of this website is part of National Chengchi University Institutional Repository. It provides free access to academic research and public education for non-commercial use. Please utilize it in a proper and reasonable manner and respect the rights of copyright owners. For commercial use, please obtain authorization from the copyright owner in advance.
2.本網站之製作,已盡力防止侵害著作權人之權益,如仍發現本網站之數位內容有侵害著作權人權益情事者,請權利人通知本網站維護人員(
nccur@nccu.edu.tw),維護人員將立即採取移除該數位著作等補救措施。
NCCU Institutional Repository is made to protect the interests of copyright owners. If you believe that any material on the website infringes copyright, please contact our staff(
nccur@nccu.edu.tw). We will remove the work from the repository and investigate your claim.