政大機構典藏-National Chengchi University Institutional Repository(NCCUR):Item 140.119/75533
English  |  正體中文  |  简体中文  |  Post-Print筆數 : 27 |  全文筆數/總筆數 : 114205/145239 (79%)
造訪人次 : 52986698      線上人數 : 669
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://nccur.lib.nccu.edu.tw/handle/140.119/75533


    題名: Clinical study of the Pronator Quadratus muscle: Anatomical features and feasibility of Pronator-Sparing Surgery
    作者: Lo, Hsien Yi;Cheng, H.-Y.
    羅賢益
    貢獻者: 神科所
    關鍵詞: article;clinical study;functional anatomy;lunate bone;muscle;orthopedic surgery;pronator quadratus muscle;pronator sparing surgery;radius fracture;scaphoid bone;surgical technique;volar plate fixation;Feasibility Studies;Fracture Fixation;Internal;Fracture Healing;Humans;Muscle;Skeletal;Prospective Studies;Radius Fractures;Treatment Outcome;Upper Extremity
    日期: 2014-04
    上傳時間: 2015-06-02 17:25:32 (UTC+8)
    摘要: Background: No clinical data for the relationship of pronator quadratus (PQ) muscle to distal radius had been reported. The aim of this study was to investigate the anatomical features of the PQ muscle related to plate osteosynthesis for distal radius fractures in clinical cases. The feasibility of PQ muscle sparing surgery was investigated as well. Methods. Fifty two distal radius fractures (23-A2) were enclosed in this study. The whole width of the muscle and the distance from the distal edge of the muscle to the joint surface of the distal radius were measured. The distance from the fracture site of the radius to the joint surface was measured as well. Results: The average width of the pronator quadratus muscle was 37.6 mm. The average distance from the pronator quadratus muscle to the lunate fossa surface was 12.2 mm, and the average distance from the pronator quadratus muscle to the scaphoid fossa surface was 13.6 mm. The average distance from the lunate fossa of the distal radius to the fracture site was 12.2 mm (range, 7.3-17 mm), and the scaphoid fossa of the distal radius to the fracture site was 13.2 mm (range, 9.4-18.8 mm). Conclusions: This PQ muscle sparing surgery is feasible and can be performed without difficulty. The data might provide a useful basis for the preservation of pronator quadratus muscle applied to a functionally reduced fracture regarding the potential efficacy of conventional volar plate osteosynthesis. © 2014 Lo and Cheng; licensee BioMed Central Ltd.
    關聯: BMC Musculoskeletal Disorders, 15(1), 834-864, 論文編號 136
    資料類型: article
    DOI 連結: http://dx.doi.org/10.1186/1471-2474-15-136
    DOI: 10.1186/1471-2474-15-136
    顯示於類別:[神經科學研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    834-864.pdf2308KbAdobe PDF2853檢視/開啟


    在政大典藏中所有的資料項目都受到原著作權保護.


    社群 sharing

    著作權政策宣告 Copyright Announcement
    1.本網站之數位內容為國立政治大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,惟仍請適度,合理使用本網站之內容,以尊重著作權人之權益。商業上之利用,則請先取得著作權人之授權。
    The digital content of this website is part of National Chengchi University Institutional Repository. It provides free access to academic research and public education for non-commercial use. Please utilize it in a proper and reasonable manner and respect the rights of copyright owners. For commercial use, please obtain authorization from the copyright owner in advance.

    2.本網站之製作,已盡力防止侵害著作權人之權益,如仍發現本網站之數位內容有侵害著作權人權益情事者,請權利人通知本網站維護人員(nccur@nccu.edu.tw),維護人員將立即採取移除該數位著作等補救措施。
    NCCU Institutional Repository is made to protect the interests of copyright owners. If you believe that any material on the website infringes copyright, please contact our staff(nccur@nccu.edu.tw). We will remove the work from the repository and investigate your claim.
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋